Utica UB90 Hot Surface Ignitor

This is a hot surface igniter for the Utica high efficiency UB90-100, UB90-125, UB90-150, UB90-175 and UB90-200 boilers. These boilers have been known to have problems with premature failure due to the ignitor being too deep into the burner. As a result the manufacturer has redesigned the new ignitor to be in less of the flame thereby dramatically increasing the life of the ignitor. Here is a link of the notice that Utica Boilers have sent out to inform people of the problem. Click here to view it at We have the new and improved hot surface ignitor for the Utica boiler in stock.

Utica UB90 High Efficiency Boiler

Utica UB90 High Efficiency Boiler

If your boiler looks like the one in the photo then chances are that you may experience ignitor problems with this boiler. Look to see if you have the grey draft inducer motor or the black one which is also a problem with the Utica boiler model UB90’s. The grey draft inducers can cause excessive vibration causing too much noise. The factory will send you a kit to absorb the vibration. If you have a black draft inducer then you do not have to worry about this problem ecause the black assemblies haev the correct shock absorbers on them. If you are looking for boiler parts for the UB90 Utica boiler and/or repair tips…. Give us a call. We are happy to assist with advise and parts. Citywide Supply & Service. Located in Chicago, Il WE STOCK THIS IGNITOR!!!